Review




Structured Review

Abbott Laboratories amplatzer ii plug
Amplatzer Ii Plug, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/amplatzer+ii+plug+vascular/pmc13264216-36-14-17
Average 86 stars, based on 1 article reviews
amplatzer ii plug - by Bioz Stars, 2026-11
86/100 stars

Images

Related Articles

other:

Article Title: Endovascular treatment of a ruptured portal vein pseudoaneurysm secondary to a large stomach ulcer.
Article Snippet: Hemostasis was achieved with an Amplatzer plug (Abbott Cardiovascular, Chicago, IL) within the hepatic parenchyma just beyond the portal vein puncture site.

Article Title: Transcirculation repair of a direct carotid-cavernous fistula in a patient who presented with hydrocephalus: illustrative case
Article Snippet: Given the injury to the right ICA, the fistula was treated by coiling through an Excelsior SL-10 microcatheter (Stryker), which was placed into the right ICA from the petrocavernous portion down to the cervical portion, with deployment of an Amplatzer plug (Abbott Cardiovascular) above the bifurcation.

Article Title: Case Report: Extensive deep vein thrombosis and venous pseudoaneurysm following percutaneous transcatheter tricuspid valve intervention
Article Snippet: Similarly, DeWane et al. described a 35-year-old woman with a large aneurysm in the left common iliac vein that was associated with a high-flow arteriovenous fistula, which was managed using an aortic stent graft and an Amplatzer plug (Abbott Cardiovascular) in the internal iliac artery to eliminate the fistula and decompress the aneurysm ( ).

Article Title: Tailored Interventional Approaches to the Management of True and False Aneurysms Affecting Aberrant Visceral Arteries Are Associated with Enhanced Clinical Outcomes
Article Snippet: Details are provided below: Endovascular approaches included coil embolization alone (7), covered stent placement (1), combined coiling of the lesion and stenting (9) or Amplatzer plug (Abbott Laboratories, Chicago, IL, USA) positioning (2) and distal splenic artery and aneurysm sac coiling with SMA stenting (1).

Article Title: Transapical to Femoral Through-and-Through Wire Technique for Ruptured Aortic Arch Aneurysm Management: Case Report and Review of Literature.
Article Snippet: Aim: To present a case where the transapical and femoral accesses were used to establish a through-and-through guidewire to deliver branched arch endograft effectively.. Case: An 86-year-old male presented with an aortic arch aneurysm rupture was treated with branched arch endograft.. Due to tortuous anatomy, several attempts using femoral and axillary routes to navigate the endograft to the proximal landing zone failed.

Article Title: Endovascular management of a traumatic lower extremity arteriovenous fistula following a machete injury
Article Snippet: The proximal anterior tibial vein was selected from above, transarterially through the AVF, and was embolized using 4-mm and 8-mm Amplatzer plugs (AVP; Abbott), whereas the ATA was embolized with a 6-mm Amplatzer plug (AVP; Abbott) and a 10 cm × 6 mm Azur coil (Terumo) delivered from the retrograde pedal access.

Article Title: Tailored Interventional Approaches to the Management of True and False Aneurysms Affecting Aberrant Visceral Arteries Are Associated with Enhanced Clinical Outcomes.
Article Snippet: Details are provided below: 1 Endovascular approaches included coil embolization alone (7), covered stent placement (1), combined coiling of the lesion and stenting (9) or Amplatzer plug (Abbott Laboratories, Chicago, IL, USA) positioning (2) and distal splenic artery and aneurysm sac coiling with SMA stenting (1).

Article Title: Endovascular treatment of a ruptured portal vein pseudoaneurysm secondary to a large stomach ulcer.
Article Snippet: Hemostasis was achieved Fig. 1 Initial portal venogram through access sheath shows patent portal system with saccular pseudoaneurysm Page 3 of 4 DuBois et al. CVIR Endovascular (2025) 8:37 with an Amplatzer plug (Abbott Cardiovascular, Chicago, IL) within the hepatic parenchyma just beyond the portal vein puncture site.



Similar Products

86
Abbott Laboratories amplatzer ii plug
Amplatzer Ii Plug, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/amplatzer+ii+plug+vascular/pmc13264216-36-14-17
Average 86 stars, based on 1 article reviews
amplatzer ii plug - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
St Jude Medical amplatzer vascular plug
Amplatzer Vascular Plug, supplied by St Jude Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/amplatzer+ii+plug+vascular/pmc13266117-24-9-12
Average 86 stars, based on 1 article reviews
amplatzer vascular plug - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer vascular plug
Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm <t>Amplatzer</t> Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .
Amplatzer Vascular Plug, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/amplatzer+ii+plug+vascular/pmc13054279-34-3-7
Average 86 stars, based on 1 article reviews
amplatzer vascular plug - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer plugs
Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm <t>Amplatzer</t> Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .
Amplatzer Plugs, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/amplatzer+ii+plug+vascular/pmc12995491-23-20-23
Average 86 stars, based on 1 article reviews
amplatzer plugs - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
St Jude Medical amplatzer plug
Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm <t>Amplatzer</t> Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .
Amplatzer Plug, supplied by St Jude Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/amplatzer+ii+plug+vascular/pmc13019489-59-4-6
Average 86 stars, based on 1 article reviews
amplatzer plug - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer vascular plug ii
(A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm <t>Amplatzer</t> Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.
Amplatzer Vascular Plug Ii, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/amplatzer+ii+plug+vascular/pmc12961297-34-13-17
Average 86 stars, based on 1 article reviews
amplatzer vascular plug ii - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer plug
(A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm <t>Amplatzer</t> Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.
Amplatzer Plug, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/amplatzer+ii+plug+vascular/pmc12995491-23-32-35
Average 86 stars, based on 1 article reviews
amplatzer plug - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer vascular plug 4
(A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm <t>Amplatzer</t> Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.
Amplatzer Vascular Plug 4, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/amplatzer+ii+plug+vascular/pm42169020-88-7-11
Average 86 stars, based on 1 article reviews
amplatzer vascular plug 4 - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer 2 plug
(A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm <t>Amplatzer</t> Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.
Amplatzer 2 Plug, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/amplatzer+ii+plug+vascular/pm42168112-31-10-13
Average 86 stars, based on 1 article reviews
amplatzer 2 plug - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results


Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm Amplatzer Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

Article Title: Black candy-plug technique for a large false lumen in a patient with complicated type B aortic dissection

doi: 10.1016/j.jvscit.2026.102212

Figure Lengend Snippet: Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm Amplatzer Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .

Article Snippet: Subsequently, a 16-mm Amplatzer Vascular Plug I (Abbott), preloaded with a 2.2F-microcatheter (Coiling Support, HI-LEX Co) was delivered through a 6F guiding catheter (Destination; Terumo Medical Co) and deployed at the waist of the modified Ex-cuff ( , D ).

Techniques: Dissection, Modification, Injection

(A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm Amplatzer Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

Article Title: Use of a physician-modified candy plug to rescue gutter leak arising from a collapsed candy plug

doi: 10.1016/j.jvscit.2026.102175

Figure Lengend Snippet: (A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm Amplatzer Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.

Article Snippet: The constrained central lumen of the physician-modified CP was plugged with an 18-mm Amplatzer Vascular Plug II (Abbott Vascular) ( , A ).

Techniques: Modification